An SMPS transformer becomes apparent at the output of all forward-mode converter. Converters applying the forward, push-pull, half-bridge and full-bridge topologies are typically forward-mode converters. Therefore, calculation of the output inductance employs the equivalent techniques for any 4 of these kinds of widely used topologies. The actual intent behind the output inductor is always to retain power for the load in the period just about every switching cycle whenever the power devices (BJTs, MOSFETs or IGBTs) are switched off. The electrical operation of the SMPS transformer is always to combine the rectangular switching pulses (pulse width modulated signals with changing duty cycle) into DC. The capacitor positioned after the inductor smooths the DC into ripple free DC.

The calculation of the SMPS transformer is pretty straightforward. More often than not, a self-gapped toroid core can be used. Gapped ferrite cores (the types employed for ferrite transformers, eg ETD39) may possibly be accustomed without problems.

The formula for determining the output inductance is:

L(min) = [Vin(max) - V(out) x T(ON) / 1.4 x Iout(min)

Transformer Design Calculator

Vin(max) = maximum voltage next to the output rectifier within that specific output.
Vout = output voltage.
Toff(est) = anticipated ON time of power device at the maximum input voltage.
Iout(min) = least heavy anticipated load current to achieve that output.

Determined from the above formula is L(min) which is the minimal recommended inductance, below which the core is going to be drained of flux at the least rated load current for that specific output.

  1. 1-Applicable procedures for calculating power and distribution transformer ratios, 2-Applicable procedures for calculating power transformer efficiency, 3-Applicable procedures for calculating power transformer voltage regulation, 4-Special Cases In Transformers Sizing Calculations: Secondary Unit.
  2. NEPSI is pleased to provide the following spreadsheet tools. The tools use Excel 2014 and are provided for various applications typically encountered in the design and application of harmonic filters. Check back from time-to-time for additional tools that will be made available on an ongoing basis!
  3. Secondary Current Calculation Size of Secondary Wire for Transformer Design Calculation a2= (4.2 A/ 2.3) = 1.83 mm2 From the standard copper wire, table it can be seen that wire of this thickness is of 15 gauge.

Make sure you plan a circuit that permits for functioning without having any load. Unquestionably, you can not replace zero for Iout(min) because that might contribute to an L(min) figure of infinity. And surely, that actually isn’t imaginable, could it be?

This transformer calculator helps you to quickly and easily calculate the primary and secondary full-load currents of the transformer. It also determines the turns ratio and type of transformer. User Instructions: Select the number of phases from the drop-down menu; Enter the transformer.

Which means that, what you need to accomplish is that you ought to decide upon the very least permissible current.

Work with a resistor load along at the output of the power source in order that should you have hardly any load, this resistor load delivers the bare minimum load.

Iout(min) needs to be significant enough that L(min) certainly is not exceedingly big; it additionally should not be exceedingly massive which may induce excessive power deficits, therefore a negative efficiency, on account of the power dissipation in the output resistor.

Commonly, this resistor is termed a dummy load whose exclusive objective is always to offer the minimal load if there is hardly any other load at the output of the converter / supply of power.

Seeing that we understand the minimum needed inductance, we should comprehend the number of turns to incorporate on our core.

Through the datasheet of the core, you will discover the AL magnitude. This signifies the inductance upon each turns squared:

AL = L/N^2

L will be the inductance and N would be the amount of turns. Implementing M as the argument:

L = √ L/AL

Thus, here is the formula which may be utilized to figure out the quantity of turns when we identify the preferred inductance.

Occasionally you probably will not be familiar with the AL valuation. You possibly will not find out the component spec the core you own thereby unable to identify the datasheet.

No matter what the explanation, it is possible to experimentally identify the AL valuation.

Execute several turns and determine using an L meter, the inductance. After that, measure the inductance for a sets of many different number of turns.

Do it again for all these selected numbers of turns. Therefore, determine the inductance for, as an example, 5, 10, 20, 40 turns after which for each and every, determine the AL value. Obtain the average AL value.

One of the things that can be done is, you might sketch a graph of L against N2. The gradient of the most effective match line could possibly be the AL value. You might also mathematically determine the gradient of the “regression line”. Exercise whatsoever course you realize is the quickest.

At this moment let’s check out a case in point to solve just what you’ve understood until at this instant.

Transformer design calculation excel format

Let’s stipulate that our converter is a half-bridge converter.

The input voltage for the converter will be different out of 150VAC (212VDC) to 250VAC (354VDC). Output voltage from the converter can be 14VDC. The turning frequency is 50kHz.

Transformer primary: 26 turns
Transformer secondary: 4+4 turns

The formula for computing the minimal essential inductance is:

L(min) = [Vin(max) - V(out) x T(ON) / 1.4 x Iout(min)

We will have to evaluate the output voltage with the transformer secondary at 354VDC input, that may be our optimum input voltage.

We’ll believe that the voltage drop as a result of the rectifier diode is 1V. Consequently the typical output voltage within the transformer secondary is 15V. Transformer turns ratio (primary: secondary) = 26:4 = 6.5

Thus, at any time typical secondary voltage is the same as 15V, typical voltage across transformer primary is 6.5 * 15V = 97.5V. In case duty cycle was 100%, voltage across transformer primary could well be 177V (50% the DC bus voltage - consider half-bridge topology). Therefore, the duty cycle is (97.5/177)*100% = 55%.

Average output voltage on transformer secondary will be 15V which has a duty cycle of 55%. Consequently, maximum output voltage is 15V/0.55 = 27.3V, and then there is assumed a diode reduction of 1V. Therefore, Vin(max) is 26.3V.

At optimum input voltage, duty cycle will probably be smallest. This can be any time the off time is going to be the greatest.

We now have determined a duty cycle value of 55% - this is actually the minimum duty cycle number. Since switching frequency is 50kHz, period of time is 20µs. The off period is 0.45 * 20µs = 9µs. Which is our Toff(est).

Let’s stipulate that the particular minimal load is going to pull 500mA current. Using a 14V output and 500mA current, the electricity dissipated in the output resistor will likely be:

P = VI = 14 x 0.5 W = 7 Watts

That is certainly a great deal of power! In case it’s agreeable, by all means employ a 500mA minimum load. If you decide to fetch the minimum load all the way down to 250mA, you trim down power dissipation (above) to 3.5W.

Therefore now we have figured out all the essential variables. Let’s connect these into the formula.

L(min) = (26.3 - 14) x 9 x 10^-6 / 1.4 x 0.25

= 316uH

This is often the bare minimum expected inductance. Feel free to use an inductance higher than the minimum number established, considering that, well you determined the minimum essential inductance.

Let’s believe we’ll exploit an inductance of 450µH. Let’s stipulate that we’ve picked out a toroid core with an AL valuation on 64nH per turn squared.

To begin with, the expected inductance is 316µH that could be equivalent to 316000nH.

Therefore the preferred range of turns is:

3 Phase Transformer Calculations Pdf

It can be possibly 70 or 71 turns. This is often for 316µH.

Regarding 450µH:

Let's make this around 84 turns.

So...now you know How to Calculate SMPS Transformer Turns at home, which you can apply this easy solution in order to determine the necessary output inductance for any converter in which employs the forward, push-pull, half-bridge or full-bridge topology. It’s effortless and also Lets hope I have personally had the opportunity to enable you to comprehend without a doubt. I want to appreciate your feedback and opinions!

The CivilWeb Foundation Design Spreadsheet Suite includes all 12 of our foundation design spreadsheets covering all major spread foundation types. Using these spreadsheets the designer can easily complete any type of foundation design in accordance with either BS EN 1997 or BS 8004. Each spreadsheet also includes unique design and analysis tools which allow the designer to optimise the designs in minutes, saving many hours of detailed design work on every foundation design.

The CivilWeb Foundation Design Spreadsheet Suite is our best value foundation design bundle and can be purchased at the bottom of this page for only £50 (80% discount). The CivilWeb Foundation Design Spreadsheet Suite includes the following spreadsheets;

Pad Footing Design Spreadsheet

Excel

This spreadsheet completes the design of single pad foundations including a central column. The column can include axial, horizontal and moment forces. The spreadsheet includes a simplified version for fast calculation of straightforward pad foundations.

Eccentric Footing Design Excel Sheet

This spreadsheet completes the design of single pad footings subject to eccentric loading. The spreadsheet allows the designer to position the column anywhere on the footing. The spreadsheet also allows the designer to analyse a footing of any polygonal shape including re-entrant corners and asymmetrical footings.

Combined Footing Design Excel Sheet

This spreadsheet completes the design of rectangular combined footings. The designer can analyse combined footings of any size with two columns placed anywhere on the footing. The columns can include axial, horizontal and moment forces.

Strap Footing Design Excel Sheet

This spreadsheet completes the design of strap footings consisting of two pad footings joined by a connecting structural concrete beam. The spreadsheet calculates the required sizes of both the pad foundations and for the connecting concrete beam. The spreadsheet calculates the bending moments and shear forces in the pads and the beam in order to design the required reinforcement.

Current Transformer Design Calculation Excel

Mat Foundation Design Spreadsheet

Transformer calculations examples

This spreadsheet can be used to complete the design of mat foundations. The designer can analyse a mat foundation of any size including up to 32 columns placed anywhere on the foundation. The columns can be subjected to axial, horizontal and moment forces. The mat foundation can be analysed as either rigid or flexible depending on the size and thickness of the mat and the strength of the subgrade.

Design of Raft Foundation Spreadsheet

This spreadsheet can be used to design raft foundation subjected to a universally distributed loading. This is suitable for houses and small buildings with a raft foundation. The raft can be designed with a universally distributed loading and linear loads at the edges and corners of the raft.

Strip Footing Design Excel Spreadsheet

This spreadsheet completes the design of strip foundations including up to 16 columns placed anywhere along the strip footing. The columns can include axial, horizontal and moment forces making this spreadsheet suitable for warehouses and other buildings with column loads on long foundations.

Wall Footing Design Spreadsheet

This spreadsheet completes the design of long footings subjected to linear loads from walls. The spreadsheet allows the design to analyse a foundation of any length and width. The wall loads are a universal linear load per metre length of wall. This spreadsheet is suitable for house and small building foundations with wall loads.

Octagonal Vertical Vessel Foundation Design Spreadsheet

This spreadsheet can be used to design octagonal foundations such as those used for vertical vessels or pipelines. The spreadsheet can be used to design octagonal foundations of any size subjected to a single column load.

Beam On Elastic Foundation Spreadsheet

This spreadsheet can be used to model a large or long foundations which behave in a flexible rather than a rigid fashion. The spreadsheet models the system as a flexible beam supported by a Winkler foundation.

Transformer Design Calculation Excel

Soil Bearing Capacity Calculation

This suite of spreadsheets includes 9 different methods of analysing the bearing capacity of soils. The spreadsheet includes 6 different analytical methods including the Terzaghi, Meyerhof and Hansen methods. The suite also includes 3 different methods of estimating the bearing capacity of soils from site investigation results.

Foundation Settlement Calculation Spreadsheet

This suite of spreadsheets includes all the tools required to complete a settlement analysis of any shallow foundation in any soil. The suite includes 6 different methods of settlement analysis including immediate, elastic, consolidation, differential, Schmertmann settlement and settlement from SI info.

CivilWeb Foundation Design Spreadsheet Suite

The CivilWeb Foundation Design Spreadsheet Suite includes all 12 of our powerful foundation design spreadsheets. The CivilWeb Foundation Design Spreadsheet Suite includes all the tools required to design any common type of shallow foundation in accordance with BS EN 1997 or BS 8004.

Buy our best value suite of foundation design spreadsheets now for only £50 (80% discount).